A straight chimney is always the best configuration on your Wiseway pellet stove. Fuel is going to be another determining factor on heat out put and performance soft pellets or Douglas fir is what the stove was tested with and performs best check your area to see if they are available, Wiseway will burn all pellets that we are aware of but varied results will be the norm. Mobile home installation also requires that a direct outside air kit be installed and the stove be bolted or fastened to the floor and a #10 copper wire be attached to the stove and then attached to the frame of the manufactured home to ground the stove. Again in certain situations this is unavoidable (Mobile Homes). Wiseway Pellet Stove Community Unlike Big Foot who is still being sought, the Wiseway Non-Electric Pellet Stove does exist. You need JavaScript enabled to view it. Direct connection to outside air in extreme cold climates can cause creosote to form or drip at times depending on the operation temperature of the stove be aware and try to operate at higher temperatures in the event this happens. Use 4 inch type L certified pellet exhaust venting system and the installation must meet local codes.

When going into a existing chimney then you must run 4" vent all the way through any existing chimney. November 01, 2020, 06:33:06 am

<>>> The Wiseway stove is fast becoming the pellet stove of choice by successfully, accomplishing what many expected from other pellet stoves and were soon disappointed when they failed. //--> A barometric damper allows you to adjust a air setting on the damper that will take more air away from the burner resulting in lower  temperature on the stove. The WiseWay. Does the Wiseway require the same flue as wood stove? document.write(''); var addy_text71798 = 'gene' + '@' + 'wisewaypelletstove' + '.' + 'com'; document.write('span>'); Does the Wiseway require a hearth under it? Designs comply with national safety standards. Where and how do you attach a cold air kit for a mobile home?

Moderators: Wiseway installation - 3" coupler on top is too large, Need to Connect or Pass through 6" wood stove Chimney Pipe. endobj What size stove pipe is needed 3” or 4”? When 8' Ft. to 12' Ft. length of chimney is used 3" diameter chimney will do, when having to use more than 15' of chimney, then 4" diameter vent is best. document.write(addy_text71798); Hard wood pellets will not deliver the same heat that soft wood pellets do and the ash content will always be higher requiring you to provide more attention and maintenance to the stove. Unlike Big Foot who is still being sought, the Wiseway Non-Electric Pellet Stove does exist. Both models retail at $1999.00 for either model with the Glass Door. 1 0 obj

Order yours today and start heating your what ever your need may be. Code calls for outside air to be available within two feet of the stove either through a wall or through the floor and if you have a energy efficient home, this not only is required but is a must. Since the chimney is the deciding factor an where the low burn temp will be with the draft wide open, the only way to lower the heat in the event you experience higher outputs on low will be to install a barometric damper directly off the top of the stove. Wiseway Pellet Stove GW1949 Model is to be installed using Pellet Vent in 3" or 4" diameter. The Wiseway Pellet Stove eliminates the need for electricity by utilizing a gravity feed … When not installed in a Alcove clearance on the right will be 16" in U.S. and 18" in Canada. Ash can build up and if not monitored the stove can loose its draw and cause smoke into the room which can be alarming. Stove can be installed in Home's, Mobile Homes in the U.S., Shops, Garage's, Tent's, Cabin's, Patio's anywhere you need heat. Stove is also Mobile home approved in the U.S. but not in Canada. Stove has clearance's to combustible as close as 3" to wall on the left, 14" to combustibles wall on the right, 2" to the wall at the back and 18" clearance to the ceiling measured from the flue collar, these are Alcove clearance's. For those wanting a blower one can be added, or by utilizing the. <>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>>